Call our helpline:
Gran transformer logo
ABN: 42147864293

DC TRANSFORMERS

coil of grant dc transformer

D.C. POWER SUPPLIES GENERAL ARRANGEMENT
AND DIMENSIONS
UNREGULATED AND UNFILTERED
STANDARD 16.0 – 600.0 WATT.

D.C. POWER SUPPLIES GENERAL ARRANGEMENT AND DIMENSIONS

1.0 Single phase input.
2.0 The wattages indicated above are nominal [max] only, actual ratings are subject to specified
requirements.
3.0 The D.C. Output voltage is constrained by the wattage rating, given that the maximum output amps
without alternative heat sinking should not exceed 5.0 amps D.C.
PDF created.

D.C. POWER SUPPLIES GENERAL ARRANGEMENT
AND DIMENSIONS
UNREGULATED AND FILTERED
STANDARD 16.0 – 600.0 WATT.

D.C. POWER SUPPLIES GENERAL ARRANGEMENT AND DIMENSIONS UNREGULATED AND FILTERED STANDARD

1.0 Single phase input.
2.0 The wattages indicated above are nominal [max] only, actual ratings are subject to specified requirements.
3.0 The D.C. Output voltage is constrained by the wattage rating, given that the maximum output amps
without alternative heat sinking should not exceed 5.0 amps D.C

D.C. POWER SUPPLIES GENERAL ARRANGEMENT
AND DIMENSIONS
UNREGULATED AND FILTERED
STANDARD 16.0 – 600.0 WATT.

D.C. POWER SUPPLIES GENERAL ARRANGEMENT AND DIMENSIONS UNREGULATED AND FILTERED STANDARD

NOTES.
1.0 Single phase input.
2.0 Wattage outputs indicated above are nominal [max] only, actual ratings are subject to specified requirements.
3.0 The D.C. output voltage is constrained by the wattage rating, given the maximum output D.C. Amps as
denoted by the frame size[ e.g. A60 is 60.0 amps D.C.].
4.0 Fuse(s) to outputs option available.
5.0 The dimension H1 is determined by the transformer selection.

D.C. POWER SUPPLIES GENERAL ARRANGEMENT
AND DIMENSIONS
UNREGULATED AND UNFILTERED OR FILTERED
STANDARD SINGLE PHASE 200 – 2800 WATT.

D.C. POWER SUPPLIES GENERAL ARRANGEMENT AND DIMENSIONS UNREGULATED AND UNFILTERED OR FILTERED STANDARD SINGLE PHASE

NOTES.
1.0 Single phase input.
2.0 Wattage outputs indicated above arenominal [max] only, actual ratings are subject to specified requirements.
3.0 The D.C. output voltage is constrained by the wattage rating, given the maximum output D.C. Amps as
denoted by the frame size[ e.g. A60 is 60.0 amps D.C.].
4.0 Fuse(s) to outputs option available up to 30.0 amps at E.L.V outputs.
5.0 Protection IP 30.

D.C.POWER SUPPLIES GENERAL ARRANGEMENT
AND DIMENSIONS
UNREGULATED AND FILTERED
STANDARD SINGLE PHASE 200 – 2800 WATT.

D.C.POWER SUPPLIES GENERAL ARRANGEMENT AND DIMENSIONS UNREGULATED AND FILTERED STANDARD SINGLE PHASE

NOTES.
1.0 Single phase input.
2.0 Wattage outputs indicated above are nominal [max] only, actual ratings are subject to specified requirements.
3.0 The D.C. output voltage is constrained by the wattage rating, Given the maximum output D.C. Amps as
denoted by the frame size[ e.g. A60 is 60.0 amps D.C.].
4.0 Fuse(s) to outputs option available.
5.0 The dimension H1 is determined by the transformer selection.
6.0 Choke or capacitor filters may be provided and at higher currents, filtering becomes limited.